Performance and Mechanisms of Ultrafiltration Membrane Fouling

Jul 11, 2017 - Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, ...
2 downloads 4 Views 2MB Size
Subscriber access provided by Binghamton University | Libraries

Article

Performance and Mechanisms of Ultrafiltration Membrane Fouling Mitigation by Coupling Coagulation and Applied Electric Field in a Novel Electrocoagulation Membrane Reactor Jingqiu Sun, Chengzhi Hu, Tiezheng Tong, Kai Zhao, Jiuhui Qu, Huijuan Liu, and Menachem Elimelech Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b01189 • Publication Date (Web): 11 Jul 2017 Downloaded from http://pubs.acs.org on July 12, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 23

Environmental Science & Technology

1 2

Performance and Mechanisms of Ultrafiltration

3

Membrane Fouling Mitigation by Coupling

4

Coagulation and Applied Electric Field in a Novel

5

Electrocoagulation Membrane Reactor

6 7 8

Jingqiu Sun1, 2, Chengzhi Hu1, 3*, Tiezheng Tong3, Kai Zhao1, Jiuhui Qu1, Huijuan

9

Liu1, Menachem Elimelech3

10

1

11

Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China 2

12 13

Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-

3

University of Chinese Academy of Sciences, Beijing 100049, China

Department of Chemical and Environmental Engineering, Yale University, New Haven,

14

Connecticut 06520-8286, United States

15 16

*Corresponding

author: e-mail address: [email protected] (C.H.); Tel: +86-10-62849160; Fax:

17

+86-10-62849160; Add: 18 Shuangqing Road, Haidian District, Beijing, 10085, P.R. China.

18

ACS Paragon Plus Environment

Environmental Science & Technology

19

ABSTRACT

20

A novel electrocoagulation membrane reactor (ECMR) was developed, in which ultrafiltration

21

(UF) membrane modules are placed between electrodes to improve effluent water quality and

22

reduce membrane fouling. Experiments with feed water containing clays (kaolinite) and natural

23

organic matter (humic acid) revealed that the combined effect of coagulation and electric field

24

mitigated membrane fouling in the ECMR, resulting in higher water flux than the conventional

25

combination of electrocoagulation and UF in separate units (EC-UF). Higher current densities

26

and weakly acidic pH in the EMCR favored faster generation of large flocs and effectively

27

reduced membrane pore blocking. The hydraulic resistance of the formed cake layers on the

28

membrane surface in ECMR was reduced due to an increase in cake layer porosity and polarity,

29

induced by both coagulation and the applied electric field. The formation of a polarized cake

30

layer was controlled by the applied current density and voltage, with cake layers formed under

31

higher electric field strengths showing higher porosity and hydrophilicity. Compared to EC-UF,

32

ECMR has a smaller footprint and could achieve significant energy savings due to improved

33

fouling resistance and a more compact reactor design.

34 35

TOC Art

36 37

1 ACS Paragon Plus Environment

Page 2 of 23

Page 3 of 23

Environmental Science & Technology

38

INTRODUCTION

39

Pressure-driven membrane filtration technologies are widely used in water treatment.1

40

Ultrafiltration (UF) in particular is commonly employed in drinking water treatment because it

41

removes multiple contaminants in one step and is economically feasible.2,

42

inherently constrained by membrane fouling, with dissolved organic substances (e.g., humic acid

43

and proteins) acting as major foulants.4-6 Membrane fouling compromises the performance and

44

lifetime of UF membranes, increasing the cost and energy demand of UF systems. Therefore,

45

effective strategies for fouling mitigation are highly desirable to improve the efficiency and

46

applicability of UF systems.7

3

However, UF is

47

Electrocoagulation (EC) is an attractive process in water treatment, and its performance and

48

mechanisms have been widely investigated.8 Since EC could effectively remove particles and

49

humic acid from raw water, applying EC as a pretreatment step is one of the promising solutions

50

to control UF membrane fouling.9-14 The properties of flocs generated by EC have a significant

51

influence on the structure of membrane cake layers and the extent of membrane fouling.9, 11 For

52

example, it has been reported that the steady-state normalized specific water flux increased from

53

51% for microfiltration to 72% for electrocoagulation-microfiltration.15 If the porosity and

54

structure of the formed cake layer can be effectively controlled in the EC process, a highly

55

porous protective layer could be formed to further alleviate membrane fouling.

56

Applied electric field has also been considered as an efficient method to reduce membrane 16-18

57

fouling.

It has been demonstrated that deposition of charged foulants, such as humic acid

58

and inorganic particles, was prevented by electrostatic repulsion induced by an electric field.19, 20

59

In this case, charged foulants migrate away from the membrane surface by electrostatic force.21,

60

22

61

fouling.23 Although electric field can alter the dipole moment of organic foulants, its effect on

62

cake layer structure has not been investigated. Furthermore, previous studies typically combined

63

EC with membrane filtration as separate units8, 24, 25, in which membranes were located outside

64

of the electric field zone. We hypothesize that when EC and UF are integrated in one unit,

65

membrane fouling would be mitigated by the combined effect of both coagulation and electric

66

field, leading to further improvement of membrane fouling control.

It was further suggested that the dipole moment of foulants can also influence membrane

2 ACS Paragon Plus Environment

Environmental Science & Technology

67

In this study, we designed an integrated electrocoagulation membrane reactor (ECMR), with

68

membrane modules placed between a pair of electrodes. We evaluated the efficiency of ECMR

69

in mitigating membrane fouling, and analyzed the effect of electrochemical parameters on the

70

ECMR performance. To better understand the antifouling mechanisms of ECMR, we focused on

71

the evolution of particle size and cake layer polarity in ECMR, which are influenced by

72

coagulation and electric field, respectively. Our study is the first to propose the concept of

73

ECMR and systematically delineate its design and working principles.

74

MATERIALS AND METHODS

75

Chemicals and Synthetic Feed Water. A stock solution of humic acid (Sigma-Aldrich,

76

U.S.A) was prepared in deionized water (DI, Millipore Milli-Q) after filtration through a 0.45

77

µm mixed cellulose ester membrane. The molecular weight of humic acid was mainly distributed

78

around ~270 kDa and ~10 kDa (Figure S1).The prepared stock solution had a dissolved organic

79

carbon (DOC) concentration of 777±20 mg/L and was stored at 4 °C until use. Sodium chloride

80

(50 mM) was added in the synthetic feed water as the background electrolyte, and sodium

81

bicarbonate (0.5 mM) was used to provide a buffer capacity. DOC of the synthetic feed water

82

was adjusted to 5 mg/L and clay (kaolinite) concentration to 50 mg/L. Sodium hydroxide and

83

hydrochloric acid were used to adjust the solution pH for experiments investigating the effect of

84

pH on ECMR performance. Sodium chloride, sodium bicarbonate, sodium hydroxide, and

85

hydrochloric acid were received at analytical pure grade; kaolinite was at chemical pure grade

86

with particle size ranging from ~400 to ~1200 nm (Figure S2). The ATR-FTIR spectra of humic

87

acid and kaolinite are presented in Figure S3. All reagents were purchased from Sinopharm

88

Chemical Regent Co., Ltd, China.

89

ECMR System and Membrane Fouling Experiments. Figure 1 describes the design

90

of the ECMR system and membrane modules. The UF membrane module was placed between

91

two plate electrodes, so that both the EC process and applied electric field could work in concert

92

to mitigate membrane fouling in one unit. When the membrane module was placed outside the

93

electrodes, the process was considered as an EC-UF system instead of ECMR. Unlike other

94

systems that combined (electro) coagulation with ultrafiltration or microfiltration10, 15, 26, EC-UF

95

was performed in one single reactor in our study. The effective volume of the reactor was 735

96

mL (14 cm ×5 cm ×10.5 cm). As shown in Figure 1b, hollow fiber membranes (PVDF, Tianjin

3 ACS Paragon Plus Environment

Page 4 of 23

Page 5 of 23

Environmental Science & Technology

97

MOTIMO Membrane Technology Co., Ltd., China) were used in the UF system. A membrane

98

module composed of ten fibers with a length of 3 cm was employed to provide an effective

99

membrane area of 24 cm2. A small tube was placed on top of the membrane module for permeate

100

collection. According to the manufacturer, the membrane average molecular weight cutoff was

101

100 kDa, which is corresponding to an average pore size of ~30 nm.

102

FIGURE 1

103

In each experiment, 1.4 L of synthetic feed water was recycled by two peristaltic pumps (36

104

mL/min) in order to generate cross-flow and keep a constant water level in the ECMR system

105

(Figure 1 and Figure S4). The membrane module was placed between two aluminum electrodes

106

parallel to the water flow, with the distance between the two electrodes fixed at 2.5 cm. The feed

107

water was well mixed by a magnetic stirrer at 300 rpm. A digital balance (ME2002E, Mettler

108

Toledo, Switzerland) connected to a personal computer was used to record the mass of permeate

109

during system operation. A pressure sensor was employed to monitor the transmembrane

110

pressure, which was maintained at 30 kPa by a peristaltic pump. The initial water flux of each

111

membrane module was 96.25 L·m-1·h-1. Unless otherwise specified, pH was adjusted to 7.0 and

112

the current density was 10 A/m2. When investigating the effects of electric field strength on

113

membrane fouling, different electrolyte concentrations were used to keep the current density

114

constant. The electrolyte concentration (measured as conductivity) exhibited little effect on water

115

flux in our experiments (Figure S5).

116

Analytical Methods. UV absorbance at 254 nm (UV254) was measured by an ultraviolet-

117

visible spectrophotometer (U-3010, Hitachi High Technologies Co., Japan) as an indicator of

118

humic acid concentration. Dissolved organic carbon (DOC, after filtration through 0.45 µm

119

mixed cellulose ester membranes) was determined with a total organic carbon (TOC) analyzer

120

(TOC-VCPH, Shimadzu, Japan).

121

In order to investigate cake layer properties, fouled membrane fibers were cut from the

122

membrane modules and dried at room temperature for 24 h. In the preparation of cross-section

123

samples of membranes, the hollow fiber membranes were frozen in liquid nitrogen, and then cut

124

instantly to preserve the cake layer attached to the membrane surface. The pristine and fouled

125

membrane samples were platinum-coated by a sputter and observed under a scanning electron 4 ACS Paragon Plus Environment

Environmental Science & Technology

126

microscope (SEM, JSM7401F, JEDL, Japan). Attenuated total reflectance Fourier transform

127

infrared (ATR-FTIR) spectra were collected by a Fourier Transform Infrared Spectrometer

128

(Nicolet 8700, Thermo Fisher Scientific, USA). Furthermore, the hydrophilicity of the fouled

129

membranes formed under different electric fields was measured by a dynamic contact angle

130

tensiometer (Data Physics DCAT, LPD Lab Services Ltd., UK). Floc size as a function of time

131

was directly monitored by a laser particle size analyzer (Mastersizer 2000, Malvern, UK).27 The

132

flocs were monitored by pumping water through the optical unit of the laser particle size

133

analyzer and back into the reactor by a peristaltic pump on the return tube (5 mm internal

134

diameter). Particle size was recorded every 20 seconds during the experiments by a computer.

135

RESULTS AND DISCUSSION

136

Performance of ECMR. The removal rate of humic acid (as measured by UV254) and

137

membrane water flux were measured to evaluate the performance of ECMR compared to EC-UF,

138

EC, and UF (Figure 2). As shown in Figure 2a, the removal rate of humic acid by ECMR

139

attained 93.7±0.2% within 10 minutes and maintained the same level afterwards. This removal

140

rate was comparable to that of EC-UF (94.0±2.5%), but significantly higher than those of EC

141

(61.1±2.9%) and UF (51.3±3.0%). For UF, size exclusion is the main mechanism for humic acid

142

removal. The low removal efficiency of humic acid by UF indicates that humic acid

143

macromolecules smaller than the membrane pore size were able to pass through the UF

144

membrane. Although higher removal efficiency (~80%) could be achieved by EC than UF,

145

longer time was needed for floc sedimentation. The ECMR and EC-UF processes combined the

146

advantages of the EC and UF processes to achieve a much higher removal efficiency of humic

147

acid within a short time.

148

FIGURE 2

149

As shown in Figure 2b, water flux decline of ECMR caused by membrane fouling was less

150

than that observed with EC-UF and UF. The flux decline curves for ECMR and EC-UF exhibited

151

two stages that corresponded to different fouling mechanisms, consistent with the pore

152

blockage–cake filtration model developed by Ho and Zydney.28 This model accounts for a

153

smooth transition of fouling mechanism from pore blockage to cake formation during filtration,

154

and has been successfully used in investigating humic acid fouling in microfiltration.29 Our

155

observation indicates that initial fouling was due to deposition of humic acid aggregates on the 5 ACS Paragon Plus Environment

Page 6 of 23

Page 7 of 23

Environmental Science & Technology

156

membrane surface blocking membrane pores, followed by formation of a cake layer on the

157

regions of membrane that had been covered by the foulant aggregates.

158

The water flux for UF alone decreased continuously within 15 min, suggesting that pore

159

blocking played a primary role. In contrast, a rapid flux decline was only observed in the

160

beginning period (i.e., the first 4-7 min) for ECMR and EC-UF. After this initial period, the

161

water flux was maintained at a relatively steady level, indicating that a cake layer had been

162

formed on the membrane surface. This two-stage mode of flux decline was consistent with the

163

results reported in other studies (Table S1).30-32 The final relative water flux, J/J0, of the ECMR

164

(87.2%) was higher than that of EC-UF (77.8%). Therefore, ECMR achieved comparable humic

165

acid rejection but provided a higher water flux than EC-UF. This finding indicates that

166

coagulation and electric field likely influence the structure and physicochemical properties of the

167

formed cake layer, which will be discussed in more detail in the following subsections.

168

Key Operational Parameters Governing EMCR Fouling Behavior. Water flux

169

decline by pore blockage mechanism depends on foulant size.33 Severe membrane fouling can be

170

caused by pore blocking when the particle size is comparable to the membrane pore size. As the

171

EC process proceeds, particle size increases in the coagulation process.34, 35 Furthermore, current

172

density and pH could control aluminum coagulant dosage and hydrolysis rate, respectively,

173

thereby leading to different sizes of generated flocs.36

174

FIGURE 3

175

As shown in Figure 3a, an increase of current density promoted fouling resistance in ECMR.

176

Under a current density of 2 A/m2, the water flux of ECMR decreased to 70.5% of the initial

177

value and kept steady afterwards. When the current density increased to 10 A/m2 and 20 A/m2,

178

the water fluxes were maintained at 83.1% and 97.3% of the original flux, respectively.

179

Furthermore, the applied current density influenced the growth of particles formed in ECMR. As

180

shown in Figure 3b, particles kept stable at first and then started to grow in size rapidly at 2 min,

181

4 min, and 11 min under current densities of 20 A/m2, 10 A/m2, and 2 A/m2, respectively.

182

Notably, this critical time for particle growth roughly matched the inflection point of the flux

183

decline curve when water flux became stable.

6 ACS Paragon Plus Environment

Environmental Science & Technology

Page 8 of 23

184

The electric field strengths varied with the different current densities applied in ECMR,

185

thereby creating two variables (electric field strength and current density) that potentially

186

influenced membrane fouling. This dependence may interfere with the interpretation of the

187

observed flux decline curves under different current densities (Figure 3). Therefore, the effect of

188

current density on water flux was investigated in EC-UF (i.e. UF membrane outside the reactor

189

and under no electric field) to exclude the concomitant influence of electric field. As shown in

190

Figure S6, the trend of flux decline under various current densities in EC-UF was consistent with

191

that in ECMR. This observation suggests that higher current densities produced more aluminum

192

coagulant species per unit time, thus enhancing aggregation of foulants (humic acid and kaolinite)

193

and reducing membrane fouling.

194 195

FIGURE 4 Solution pH also influenced EMCR performance because pH governs the coagulation

196

mechanisms and the growth of particles by metal salt coagulants.35,

37, 38

197

previous work38, lower solution pH resulted in a more rapid growth of flocs with a more porous

198

structure, which might contribute to the mitigation of membrane fouling. As shown in Figure 4a,

199

J/J0 reached a steady state of 94.7% at pH 4.0, whereas it decreased to 87.6% and 77.4% at pH

200

7.0 and 9.0, respectively. Figure 4b shows that the particle size kept small initially and then

201

started to grow rapidly at 2 min, 4 min, and 6 min for pH at 4.0, 7.0, and 9.0, respectively.

202

Consistent with the phenomenon observed in Figure 3, the time when particle size started to

203

increase roughly matched the inflection point of the flux decline curves for every pH, which

204

underscores the importance of particle size in reducing membrane fouling in ECMR.

According to our

205

Our results demonstrate that current density and solution pH are two critical parameters for

206

membrane fouling control in ECMR. Hence, proper control of these operational parameters

207

could be used to optimize membrane resistance to pore blocking.

208

Cake Layer Properties under Applied Electric Field. Water flux decline curves

209

under various initial electric field strengths are presented in Figure 5. The current density was

210

kept constant, whereas the electric field strength was varied by altering the electric conductivity

211

of the feed solutions. Electrolyte concentration (measured as conductivity) exhibited negligible

212

effect on membrane fouling and humic acid removal in our experiments (Figure S5 and S7). 7 ACS Paragon Plus Environment

Page 9 of 23

Environmental Science & Technology

213

Feed solutions with lower conductivities resulted in stronger electric field strengths. Results

214

show that the final normalized water flux (J/J0) was positively correlated to the initial strength of

215

the electric field. Specifically, J/J0 values were 85.4%, 91.0%, and 94.9% under electric field

216

strengths of 0.5 V/cm, 1 V/cm, and 2 V/cm, respectively. Polarization effects induced by the

217

electric field likely played an important role in membrane fouling, especially during the process

218

of cake layer formation, as also recently observed by Fan et al.20. To further explore this

219

observation, we analyzed the morphology and hydrophilicity of the fouled membranes in order to

220

understand the alteration of cake layer properties under different electric fields.

221

FIGURE 5

222

The surface morphologies of the fouled membranes subjected to different electric field

223

strengths were observed by SEM (Figure 6a-c). The cake layers formed under different electric

224

field showed similar compositions (Figure S8). But when the strength of electric field increased,

225

the cake layer showed a more irregular and rougher surface with enhanced porosity. The

226

observed average pore sizes of the cake/fouling layers were 7.9 nm, 12.6 nm, and 12.8 nm under

227

electric field strengths of 0.5 V/cm, 1 V/cm, and 2 V/cm, respectively (Figure S9). Also, the

228

thickness of cake layers was larger at higher electric field strengths (Figure 6d-f).

229

FIGURE 6

230

As the electric field increases, the structure of the formed cake layers is increasingly

231

influenced by orientation polarization.40 Negatively charged functional groups would orient

232

toward the anode and positively charged groups would orient toward the cathode, which results

233

in more functional groups oriented parallel to the direction of electric field. In addition, the

234

surface charge of the foulants could be enhanced by displacement polarization.41 The foulant

235

molecules would be stretched along the direction of electric field, and the end functional groups

236

on foulants could concentrate more charges. Therefore, the interaction between foulants is

237

strengthened in the direction parallel to electric field. In contrast, this interaction was weakened

238

perpendicular to electric field, resulting in an increased pore size of cake layers. According to

239

this mechanism, charged foulants under higher electric field strengths were more prone to be

240

connected to attach to the membrane surface, contributing to an increase of cake layer thickness.

241

FIGURE 7 8 ACS Paragon Plus Environment

Environmental Science & Technology

Page 10 of 23

242

Figure 7 indicates that cake layers formed under higher electric field strengths were more

243

hydrophilic than those formed at a lower electric field strength. As the electric field strength

244

increased from 0.5 V/cm to 2 V/cm, the water contact angle of the fouled membrane surface

245

decreased from 114.7±5.3 ° to 99.4±6.3 ° (Figure 7a). It has been reported that a more

246

hydrophilic cake layer resulted in a greater membrane fouling resistance in UF.42 Furthermore,

247

ATR-FTIR was used to characterize the surface functionality of the fouled membranes. The

248

peaks at 2850~2880 cm-1, 2930 cm-1 (aliphatic C-H stretching), and 3300 cm-1 (O-H stretching

249

vibration), which are characteristic for humic substances,36, 43-45 showed higher signals as the

250

electric fields increased from 0 V/cm to 2 V/cm (Figure 7b). This result indicates an increase of

251

humic acid amount in the cake layers, which was in agreement with the thicker cake layer

252

observed at higher electric field strengths. Many functional groups of humic acid, such as

253

carboxyl, hydroxyl and amine groups, are known to be influenced by electric field,40 in particular

254

hydroxyl and amide groups that have higher electric dipole moments and are more readily

255

polarized. In addition, charge distribution with foulant (humic acid) molecules was induced by

256

the applied electric field, resulting in more charges being concentrated at both ends of the

257

molecules along electric field direction. These polarized functional groups rendered humic acid

258

more inclined to attach to the membrane surface at higher electric fields due to the stronger

259

electrostatic force. As a result, cake layers with higher polarity were formed, exhibiting high

260

affinity to water molecules and subsequently improving water permeability. An illustration of the

261

proposed mechanism for the impact of electric field on fouling is summarized in Figure 8.

262

FIGURE 8

263

ECMR Fouling Mitigation Mechanisms and Implications for System Operation

264

and Design. Particle size, which performed as a key factor in reducing membrane fouling in

265

ECMR, was controlled by the current density and solution pH. Particles with sizes larger than the

266

membrane pore size reduced membrane pore blocking and facilitated the formation of a cake

267

layer that served as a protective layer. Meanwhile, a loose and hydrophilic cake layer was

268

formed in ECMR, due to oriented polarization of foulants under the electric field. Charged

269

foulants on the membrane surface were aligned in accordance with the direction of the applied

270

electric field. The increased cake layer polarity induced by both coagulation and electric field

271

further improved the affinity of the membranes to water. Therefore, the combined effect of 9 ACS Paragon Plus Environment

Page 11 of 23

Environmental Science & Technology

272

coagulation and electric field in ECMR improved the fouling resistance of UF the membrane and

273

resulted in a higher water flux.

274

ECMR not only improves removal efficiency of organic matter but also greatly mitigates

275

membrane fouling. ECMR performs better at high current densities and under weakly acidic pH

276

conditions. It is also feasible to further minimize membrane pore blocking by starting the

277

membrane filtration process after the floc size becomes larger than the membrane pore size.

278

Furthermore, increasing the applied voltage can result in a more hydrophilic cake layer. The

279

above operation conditions favor effective mitigation of membrane fouling in practice.

280

Water production per unit volume of reactor can be increased with the design of multiple

281

electrodes and membrane modules in the ECMR. The energy consumption per unit water

282

production for ECMR at 2 A/m2 was comparable to that of EC-UF. When applying current

283

densities of 10 A/m2 and 20 A/m2, ECMR reduces energy consumption by 6.4% and 1.3%,

284

respectively, compared to EC-UF (Supporting information Table S2 and Equation S8). Therefore,

285

energy savings could be achieved by changing the water treatment system configuration from

286

EC-UF to ECMR. In addition, the land use of ECMR will be reduced due to a more compact

287

reactor design.

288 289

ASSOCIATED CONTENT

290

Supporting information available: molecular weight distribution of humic acid (Figure S1);

291

particle size distribution of kaolinite (Figure S2); ATR-FTIR spectra of humic acid and kaolinite

292

(Figure S3); supplementary scheme for the design of ECMR (Figure S4); normalized water flux

293

decline curves at different electric conductivity (Figure S5); calculation of particle size for light

294

scattering measurements; fitted parameters for pore blocking resistance-limited model (Table

295

S1); normalized water flux decline curves at different current densities in EC-UF (Figure S6);

296

influence of ionic strength on EC (Figure S7); energy dispersion spectrum analysis (Figure S8);

297

pore size analysis (Figure S9); parameters for energy consumption calculation (Table S2). This

298

material is available free of charge via the internet at http://pubs.acs.org.

299 300

AUTHOR INFORMATION 10 ACS Paragon Plus Environment

Environmental Science & Technology

301

Corresponding Author

302

*Chengzhi Hu, Phone: +86-10-62849160; fax: +86-10-62849160; email: [email protected].

303

Author Contributions

304

The manuscript was written through contributions of all authors. All authors have given approval

305

to the final version of the manuscript.

306 307

ACKNOWLEDGMENT

308

The authors are grateful for financial support from the National Natural Science Foundation of

309

China (No. 51678556 and 51438011) and the Major Science and Technology Program for Water

310

Pollution Control and Treatment (2015ZX07402003-3).

311

11 ACS Paragon Plus Environment

Page 12 of 23

Page 13 of 23

Environmental Science & Technology

312

REFERENCES

313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357

1. Shannon, M. A.; Bohn, P. W.; Elimelech, M.; Georgiadis, J. G.; Marinas, B. J.; Mayes, A. M., Science and technology for water purification in the coming decades. Nature 2008, 452, (7185), 301-310. 2. Van der Bruggen, B.; Everaert, K.; Wilms, D.; Vandecasteele, C., Application of nanofiltration for removal of pesticides, nitrate and hardness from ground water: rejection properties and economic evaluation. J. Membr. Sci. 2001, 193, (2), 239-248. 3. Zhang, Q.; Vecitis, C. D., Conductive CNT-PVDF membrane for capacitive organic fouling reduction. J. Membr. Sci. 2014, 459, 143-156. 4. Saravia, F.; Zwiener, C.; Frimmel, F. H., Interactions between membrane surface, dissolved organic substances and ions in submerged membrane filtration. Desalination 2006, 192, (1-3), 280-287. 5. Jermann, D.; Pronk, W.; Meylan, S.; Boller, M., Interplay of different NOM fouling mechanisms during ultrafiltration for drinking water production. Water Res. 2007, 41, (8), 17131722. 6. Peiris, R. H.; Halle, C.; Budman, H.; Moresoli, C.; Peldszus, S.; Huck, P. M.; Legge, R. L., Idendifying fouling events in a membrane-based drinking water treatment process using principal component analysis of fluorescence excitation-emission matrices. Water Res. 2010, 44, (1), 185-194. 7. Chung, C. M.; Tobino, T.; Cho, K.; Yamamoto, K., Alleviation of membrane fouling in a submerged membrane bioreactor with electrochemical oxidation mediated by in-situ free chlorine generation. Water Res. 2016, 96, 52-61. 8. Bagga, A.; Chellam, S.; Clifford, D. A., Evaluation of iron chemical coagulation and electrocoagulation pretreatment for surface water microfiltration. J. Membr. Sci. 2008, 309, (1-2), 82-93. 9. Gamage, N. P.; Chellam, S., Aluminum electrocoagulation pretreatment reduces fouling during surface water microfiltration. J. Membr. Sci. 2011, 379, (1-2), 97-105. 10. Ben Sasson, M.; Adin, A., Fouling mechanisms and energy appraisal in microfiltration pretreated by aluminum-based electroflocculation. J. Membr. Sci. 2010, 352, (1-2), 86-94. 11. Hua, L.-C.; Huang, C.; Su, Y.-C.; Tran-Ngoc-Phu, N.; Chen, P.-C., Effects of electrocoagulation on fouling mitigation and sludge characteristics in a coagulation-assisted membrane bioreactor. J. Membr. Sci. 2015, 495, 29-36. 12. Huang, H.; Schwab, K.; Jacangelo, J. G., Pretreatment for Low Pressure Membranes in Water Treatment: A Review. Environ. Sci. Technol. 2009, 43, (9), 3011-3019. 13. Chellam, S.; Sari, M. A., Aluminum electrocoagulation as pretreatment during microfiltration of surface water containing NOM: A review of fouling, NOM, DBP, and virus control. J. Hazard. Mater. 2016, 304, 490-501. 14. Ibeid, S.; Elektorowicz, M.; Oleszkiewicz, J. A., Electro-conditioning of activated sludge in a membrane electro-bioreactor for improved dewatering and reduced membrane fouling. J. Membr. Sci. 2015, 494, 136-142. 15. Sari, M. A.; Chellam, S., Surface water nanofiltration incorporating (electro) coagulationmicrofiltration pretreatment: Fouling control and membrane characterization. J. Membr. Sci. 2013, 437, 249-256. 16. Bani-Melhem, K.; Elektorowicz, M., Development of a Novel Submerged Membrane Electro-Bioreactor (SMEBR): Performance for Fouling Reduction. Environ. Sci. Technol. 2010, 44, (9), 3298-3304. 12 ACS Paragon Plus Environment

Environmental Science & Technology

358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403

Page 14 of 23

17. Liu, L.; Liu, J.; Gao, B.; Yang, F.; Chellam, S., Fouling reductions in a membrane bioreactor using an intermittent electric field and cathodic membrane modified by vapor phase polymerized pyrrole. J. Membr. Sci. 2012, 394, 202-208. 18. Ronen, A.; Duan, W.; Wheeldon, I.; Walker, S.; Jassby, D., Microbial Attachment Inhibition through Low-Voltage Electrochemical Reactions on Electrically Conducting Membranes. Environ. Sci. Technol. 2015, 49, (21), 12741-12750. 19. Chen, J.-P.; Yang, C.-Z.; Zhou, J.-H.; Wang, X.-Y., Study of the influence of the electric field on membrane flux of a new type of membrane bioreactor. Chem. Eng. J. 2007, 128, (2-3), 177-180. 20. Fan, X.; Zhao, H.; Quan, X.; Liu, Y.; Chen, S., Nanocarbon-based membrane filtration integrated with electric field driving for effective membrane fouling mitigation. Water Res. 2016, 88, 285-292. 21. Tsai, Y.-T.; Weng, Y.-H.; Lin, A. Y.-C.; Li, K.-C., Electro-microfiltration treatment of water containing natural organic matter and inorganic particles. Desalination 2011, 267, (2-3), 133-138. 22. Chen, X.; Deng, H., Removal of humic acids from water by hybrid titanium-based electrocoagulation with ultrafiltration membrane processes. Desalination 2012, 300, 51-57. 23. Nghiem, L. D.; Schafer, A. I.; Elimelech, M., Pharmaceutical retention mechanisms by nanofiltration membranes. Environ. Sci. Technol. 2005, 39, (19), 7698-7705. 24. Zhu, B. T.; Clifford, D. A.; Chellam, S., Comparison of electrocoagulation and chemical coagulation pretreatment for enhanced virus removal using microfiltration membranes. Water Res. 2005, 39, (13), 3098-3108. 25. Tanneru, C. T.; Rimer, J. D.; Chellam, S., Sweep Flocculation and Adsorption of Viruses on Aluminum Flocs during Electrochemical Treatment Prior to Surface Water Microfiltration. Environ. Sci. Technol. 2013, 47, (9), 4612-4618. 26. Chen, Y.; Dong, B. Z.; Gao, N. Y.; Fan, J. C., Effect of coagulation pretreatment on fouling of an ultrafiltration membrane. Desalination 2007, 204, (1-3), 181-188. 27. Yu, W.; Hu, C.; Liu, H.; Qu, J., Effect of dosage strategy on Al-humic flocs growth and re-growth. Colloids and Surfaces a-Physicochemical and Engineering Aspects 2012, 404, 106111. 28. Ho, C. C.; Zydney, A. L., A combined pore blockage and cake filtration model for protein fouling during microfiltration. J. Colloid Interface Sci. 2000, 232, (2), 389-399. 29. Yuan, W.; Kocic, A.; Zydney, A. L., Analysis of humic acid fouling during microfiltration using a pore blockage-cake filtration model. J. Membr. Sci. 2002, 198, (1), 51-62. 30. Lee, S.; Cho, J. W.; Elimelech, M., Combined influence of natural organic matter (NOM) and colloidal particles on nanofiltration membrane fouling. J. Membr. Sci. 2005, 262, (1-2), 2741. 31. Xiao, F.; Xiao, P.; Zhang, W. J.; Wang, D. S., Identification of key factors affecting the organic fouling on low-pressure ultrafiltration membranes. J. Membr. Sci. 2013, 447, 144-152. 32. Yuan, W.; Zydney, A. L., Humic acid fouling during microfiltration. J. Membr. Sci. 1999, 157, (1), 1-12. 33. Howe, K. J.; Marwah, A.; Chiu, K.-P.; Adham, S. S., Effect of coagulation on the size of MF and UF membrane foulants. Environ. Sci. Technol. 2006, 40, (24), 7908-7913. 34. Xu, Y.; Chen, T.; Cui, F.; Shi, W., Effect of reused alum-humic-flocs on coagulation performance and floc characteristics formed by aluminum salt coagulants in humic-acid water. Chem. Eng. J. 2016, 287, 225-232. 13 ACS Paragon Plus Environment

Page 15 of 23

404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432

Environmental Science & Technology

35. Ching, H. W.; Elimelech, M.; Hering, J. G., Dynamics of Coagulation of Clay Particles with Aluminum Sulfate. J. Environ. Eng. 1994, 120, (1), 169-189. 36. Tremblay, L.; Alaoui, G.; Leger, M. N., Characterization of Aquatic Particles by Direct FTIR Analysis of Filters and Quantification of Elemental and Molecular Compositions. Environ. Sci. Technol. 2011, 45, (22), 9671-9679. 37. Cao, B.; Gao, B.; Liu, X.; Wang, M.; Yang, Z.; Yue, Q., The impact of pH on floc structure characteristic of polyferric chloride in a low DOC and high alkalinity surface water treatment. Water Res. 2011, 45, (18), 6181-6188. 38. Hu, C.; Sun, J.; Wang, S.; Liu, R.; Liu, H.; Qu, J., Enhanced efficiency in HA removal by electrocoagulation through optimizing flocs properties: Role of current density and pH. Sep. Purif. Technol. 2017, 175, 248-254. 39. Chen, M.-Y.; Lee, D.-J.; Yang, Z.; Peng, X. F.; Lai, J. Y., Fluorecent staining for study of extracellular polymeric substances in membrane biofouling layers. Environ. Sci. Technol. 2006, 40, (21), 6642-6646. 40. de Menezes, V. M.; Mota, R.; Zanella, I.; Fagan, S. B., Pristine and functionalized capped carbon nanotubes under electric fields. Phys. Status Solidi B 2014, 251, (3), 649-654. 41. Li, H.; Hu, T.; Zhang, R.; Liu, J.; Hou, W., Preparation of solid-state Z-scheme Bi2MoO6/MO (M=Cu, Co3/4, or Ni) heterojunctions with internal electric field-improved performance in photocatalysis. Appl. Catal. B: Environ. 2016, 188, 313-323. 42. Peter-Varbanets, M.; Margot, J.; Traber, J.; Pronk, W., Mechanisms of membrane fouling during ultra-low pressure ultrafiltration. J. Membr. Sci. 2011, 377, (1-2), 42-53. 43. Litvin, V. A.; Minaev, B. F., Spectroscopy study of silver nanoparticles fabrication using synthetic humic substances and their antimicrobial activity. Spectrochim. Acta A 2013, 108, 115-122. 44. Hatch, C. D.; Gierlus, K. M.; Zahardis, J.; Schuttlefield, J.; Grassian, V. H., Water uptake of humic and fulvic acid: measurements and modelling using single parameter Kohler theory. Environ. Chem. 2009, 6, (5), 380-388. 45. Jarusutthirak, C.; Amy, G., Role of soluble microbial products (SMP) in membrane fouling and flux decline. Environ. Sci. Technol. 2006, 40, (3), 969-974.

433 434

14 ACS Paragon Plus Environment

Environmental Science & Technology

Page 16 of 23

435 436

Figure 1. Schemes for (a) the design of ECMR system: 1.4 L of synthetic feed water was recycled by two

437

peristaltic pumps (36 mL/min) in order to generate cross-flow and keep a constant water level in the

438

ECMR system. The membrane module was placed between two aluminum electrodes parallel to the water

439

flow, with the distance between the two electrodes fixed at 2.5 cm. A pressure sensor was employed to

440

monitor the transmembrane pressure, which was maintained at 30 kPa by a peristaltic pump. Permeate

441

water was generated via peristaltic pump from UF membrane module and weighted by a digital balance,

442

which connected to a computer. (b) Hollow fiber membrane module (one eighth was cut off in order to

443

exhibit the inside structure of the membrane module). Water passed through membranes from the fiber

444

outside (brown arrow), flowed inside the membranes (purple arrow) and was collected by a small tube on

445

top of the membrane module (blue arrow).

446

15 ACS Paragon Plus Environment

Page 17 of 23

Environmental Science & Technology

(a)

UF EC EC-UF ECMR

1.0 0.8

C/C0

0.6 0.4 0.2 0.0 0

Normalized Water Flux

1.1

10

20

30

40

50

(b)

60

ECMR EC-UF UF

1.0 0.9 0.8 0.7 0.6 0.5 0

447

2

4

6

8

10

12

14

Time (min)

448

Figure 2. (a) Removal rate of humic acid (as measured by UV254) by UF, EC, EC-UF, and ECMR.

449

Removal rates were obtained from three independent fouling experiments. (b) Final relative water flux

450

(J/J0) of ECMR and EC-UF at 10 A/m2 and UF alone. Feed water was composed of sodium chloride (50

451

mM), sodium bicarbonate (0.5 mM), humic acid (5 mg/L DOC), and kaolinite (50 mg/L). Initial solution

452

pH was 7.0 and temperature was kept at 25 °C.

453

16 ACS Paragon Plus Environment

Environmental Science & Technology

Page 18 of 23

454 455

Figure 3. (a) Normalized water flux decline curves at different current densities in ECMR; (b) particle

456

size evolution with time at different current densities at initial pH 7. Feed solution composition is

457

described in the caption of Figure 2.

458

17 ACS Paragon Plus Environment

Page 19 of 23

Environmental Science & Technology

459 460

Figure 4. (a) Normalized water flux decline curves under different initial solution pH; (b) particle size

461

evolution with time under different initial solution pH at 10 A/m2. Feed solution composition is described

462

in the caption of Figure 2.

463

18 ACS Paragon Plus Environment

Environmental Science & Technology

Page 20 of 23

464 465

Figure 5. Normalized water flux decline curves under different initial electric field strengths. The

466

corresponding initial electric conductivities were 500, 1000, and 2000 µS/cm for 2.00 V/cm, 1.00 V/cm,

467

and 0.50 V/cm, respectively; current density was 10 A/m at pH 7.0. Feed solution composition is

468

described in the caption of Figure 2.

2

469

19 ACS Paragon Plus Environment

Page 21 of 23

Environmental Science & Technology

470 471

Figure 6. Scanning electron microscopy (SEM) images of fouled hollow fiber membrane surface under

472

electric fields of (a) 0.5 V/cm, (b) 1 V/cm, and (c) 2 V/cm and cross-sections under electric fields of (d)

473

0.5 V/cm, (e) 1 V/cm, and (f) 2 V/cm, respectively. The corresponding initial conductivities were 500,

474

1000, and 2000 µS/cm, for 2 V/cm, 1 V/cm, and 0.5 V/cm, respectively; current density was 10 A/m2 at

475

pH 7.0 and experiment time was 30 min. Feed solution composition is described in the caption of Figure

476

2.

477

20 ACS Paragon Plus Environment

Environmental Science & Technology

Page 22 of 23

478 479

Figure 7. (a) Contact angle and (b) attenuated total reflectance Fourier transform infrared spectroscopy

480

(ATR-FTIR) spectra of fouled membranes at different initial electric fields. The corresponding initial

481

conductivities were 500, 500, 1000, and 2000 µS/cm, for 0 V/cm, 2 V/cm, 1 V/cm, and 0.5 V/cm,

482

respectively; the current density was 10 A/m2 at pH 7.0. Contact angle measurements were repeated three

483

times.

484 21 ACS Paragon Plus Environment

Page 23 of 23

Environmental Science & Technology

485 486

Figure 8. Schematic description of the proposed mechanisms for membrane fouling mitigation in ECMR.

22 ACS Paragon Plus Environment