New Products: New Products - Analytical Chemistry (ACS Publications)

Note: In lieu of an abstract, this is the article's first page. Click to increase image size Free first page. View: PDF | PDF w/ Links. Article Option...
0 downloads 0 Views 9MB Size
New

Products

Gel documentation UVIdoc is a modular gel-documentation system consisting of a light-tight darkroom that clamps over a transilluminator for viewing DNA, RNA, protein gels, ELISA plates, spots, and blots. Internal illumination is provided by whiie llght tubes for easy positioning of the gels, and the light-tight front door allows access to the light box to change gel media. The system comes with a 312-nm transilluminator for viewing ethidium bromide stained gels, but the transilluminator can be changed to one with a different wavelength. The CCD camera is an integral part of the darkroom and has a rotary control to change exposure levels for faint bands or media that require longer exposure. DNA levels of < 0.01 n1 nan be resolved. Output modes from the darkroom include black-and-white video; a printer that uses heat-sensitive film; ;nd direct townloading onto o computer using Windows-based Imagelink software, which can save the

INSTRUMENTATION Autosampler Alltech 570 autosampler features sample cooling, trays for 5-mL vials, and metalfree fluid path options and can inject up to 96 samples. Alltech • 407 MS detector HP 5973 mass-selective detector, with an 800-amu mass range, is designed to be combined with the HP 6890 gas chromatography to create a benchtop system. The 5973 is equipped with a 250-L/s turbomolecular pump and can accept up to 4 mL/ min helium flow into the vacuum system. Features include a metalized gold quadruple, independent heating of the quadru564 A

mission, specular reflectance, large-angle reflectance, Raman, and irradiation. The 2000-A can be used in all optical ranges and fits all popular spectrometers. Fully demountable windows allow selection of spectral regions, and the experimental chamber isformedfrom a single piece of stainless steel. AABSPEC 1 4 1 0

image in a format that is compatible with other software packages. A frame grabber inside the computer is not required. The printer is connected directly to the system rather than through a computer, so a driver is not required. Gel analysis software is also available. UVItec • 408

Micromachining QuikLaze, a muMwavelength Nd:YAGbased laser micromachining system, can be used at 355 nm, 532 nm, and 1064 nm with pulse widths of 7,6, and 5 ns, respectively, and can make cuts as small as 1 x 1 um. Energy ranges from 0.6-0.4 mjj and pulse repetition rates are up to 20 Hz. QuikLaze is designed to operate with the Mitutoyo FS60, as well as with the A-Zoom microscopes. New Wave Research • 411 Spectrometer The digital signal acquisition and processing capabilities of the SLM-Aminco 48000 DSCF provide measurement of lifetimes in the microsecond to picosecond ranges. Dynamic anisotropy measurement using optional polarizers is fully supported. Spectronic 4 1 2

pole analyzer and ion source, short capillary direct interface, a high-energy dynode electron multiplier detector, easier access for maintenance and repair, and an optional large-capacity programmable temperature vaporization inlet. The system is designed to provide picogram-level sensitivity using the positive and negative chemical ionization accessory and femtogram-level sensitivity in the electron ionization selected ion monitoring mode. Hewlett Packard • 409

Minispectrometer The Plug & Play series of portable spectrometers is based on a single-strand optical fiber and a compact optical bench anchored by a 1024-element CCD array detector. The appropriate sensor or sample cell is connected to the input fiber using a standard SMA connector. In addition to three spectrometer platforms (PC plug-in, notebook PC via PCMCIA card, and PC

FT-IR The 2000-A Multi-Mode FT-IR System has a temperature range of-170 to 950 °C and a pressure range of high vacuum to 2000 psig. Optical modes include trans-

For more information, please circle the appropriate numbers on one of our Reader Service Cards.

Analytical Chemistry News & Features, September 1, 1996

via A/D board interface), components to choose from include 14 diffraction gratings, four light sources, and more than 150 fiber-optic accessories. The spectrometers measure 13 x 14 x 4 cm. Ocean Optics 4 1 3 Wet chemistry on a card PC Meters are credit card-sized instruments that consist of a sensor interfaced to a Type II PCMCIA card that can be plugged into a desktop, laptop, or handheld computer. Cards are available to measure pH, conductivity, oxidationreduction potential, and temperature. Nomadics 4 1 4

LITERATURE Pyrolysis GC Application note describes analysis of cosmetics by pyrolysis GC using the Pyroprobe. Low-temperature pyrolysis is used to remove lower boiling-point constituents, and high-temperature pyrolysis fragments the polymers in mascara samples. CDS Analytical • 415 Scanning probe microscopy Topics covered in the guidebook "A Practical Guide to Scanning Probe Microscopy"

Microplate reader BioLumin 960 can read microplates in absorbance, fluorescence, or both modes simultaneously in 12 s. The microplates automatically align for reading as the sample loading drawer closes, and the reading chamber is temperature-controlled from ambient room temperature to 45 °C. The reader is designed for sensitivity down to 1 fm fluorescent dye. An optional RS-232 interface allows synchronized robotic operation. Xperi-

include scanning tunneling, atomic force, magnetic force, and lateralforcemicroscopies; force modulation techniques; phase detection; electrostatic force; scanning capacitance;tiiermalscanning; near-field scanning; and nanolithography. The book is also available on the Internet at www. park.com. Park Scientific Instruments • 416

CATALOGS Optics Catalog features optical components and instruments for UV, visible, and IR spectroscopies and includes references, concave holographic gratings, filter-specific application sets, microlens arrays, monochromators, and microlenses. Optometries 4 1 7 LC SynChropak HPLC columns catalog describes biocompatible packed and capillary columns. Products include reversedphase; size exclusion; ion, anion, and cation exchange; hydrophobic interaction; preparative columns; guard columns; peptide standards; a postcolumn reactor; and reference books. MICRA Scientific • 418

GC The SnapShot gas chromatograph is a handheld air analyzer that weighs < 10 lbs and is designed for workplace safety and environmental applications such as monitoring air emissions at leaking underground storage tanks. Four application modules allow detection of specific compounds, and the original programmed modules include a compound library, analysis setup, and analytical method software. The 1,3-butadiene module operates without interference from other C4 hydrocarbons and has a detection range of 1-50 ppm. The methyl tertt butyl ether module has a detection range of 10-100 ppm, and the styrene module has a detection range of 1-60 ppm. The propylene oxide module, designed to operate without interference from isobutylene, methanol,terf-butylhydroperoxide, C,-C4 aldehydes,tert-butylalcohol, and other solvents, has a detection range of 0.5-100 ppm. Analysis ttmes are 5-14 min. Perkin Elmer • 420

ment software for Macs provides system control, data analysis, and standardized result printouts. Molecular Dynamics 1 4 1 9

Analytical Chemistry News & Features, September 1, 1996 5 6 5 A